CAL 9500
Temperature and Process Controller
Temperature Control
Applications Notes
All West Controllers
All CAL Controllers
Ramp and Soap
--- Full PID --- Temperature and Process Controller
|
 |
Features of the 9500P programmable process controller
|
 |
 |
Programmer Features
- Up to 31 programs
(profiles)
- Up to 126 segments
- Unlimited use of
event outputs via the 2nd and 3rd outputs
- Copy/paste/edit/delete
functions to simplify program building
- Call another program
as a sub-program segment
- Up to 999 program
loop cycles, or continuous loop cycling
- Hold back function to
ensure the next segment is not started until the last segment reaches set-point
- 3 power fail recovery
options, (hold, continue or reset)
- Front Panel
Interrogation of the program position
- Memory usage
indication during programming
- Front panel 'release
from hold' function to run the program.
|
|
|
|
9500P programmable process controller
|
|
1/16th DIN 48 x 48mm
|
|
Set-point and process value shown.
|
| Options: |
Thermocouple/PT100 |
| Inputs: |
0-5,
0-10, 4-20mA (0-20-A) |
| Outputs: |
(third is
always relay)
Outputs 1 & 2 a combination from:
SSR driver, relay, 4-20mA, 0-5V, 0-10V |
| Communications: |
RS232,
RS485 with MODBUS RTU protocol |
|
|
Specifications - 9500P |
| Thermocouple |
RTD |
Linear Process Inputs * |
|
9 types:
|
B,E,J,K,L,N,R,S,T
|
RTD/PT100
|
2 & 3
wire
|
Options:
|
0 to 50mV
+/-0.1%
|
|
Standards:
|
IPTS/68/
DIN 43710
|
Standards
|
DIN43760
(-200/400°C)
|
|
4-20mV/mA
+/-0.1%
|
|
CJC
rejection:
|
20:1 (0.05°/°C) typical
|
|
|
|
0-5V
+/-0.1%
|
|
External resistance
|
100 ohms
maximum
|
|
|
|
0-10V
+/-0.1%
|
|
|
|
|
|
* Use 1 ohm external shunt for mA
|
|
Inputs: (SM = sensor
maximum) |
|
Calibration
accuracy: |
+/- 0.25%
SM +/-1°C |
|
Sampling
frequency: |
input
10Hz, CJC 2 sec. |
|
Common
mode rejection: |
Negligible
effect up to 140db, 240V, 50-60Hz |
|
Series
mode rejection: |
60db,
50-60Hz |
|
Temperature
coefficient: |
50ppm/°C
SM typical |
|
Reference
conditions: |
22°C +/-
2°C, rated voltage after 15 minutes settling time. |
|
Outputs: (check configuration) |
|
SSd1 and
SSd2 |
solid
state relay driver: to switch a remote SSR 6VDC (nominal) 20mA non-isolated |
|
Miniature
power relay: |
form
A/SPST contacts (AgCdO) |
|
rLY1,
rLY2, rLT3: |
2A/250VAC
resistive load |
|
Analog
output: |
4-20mA
500 ohms max +/- 0.1% fs |
|
0-5Vdc
10mA (500 ohms min) +/- 0.1% fs |
|
0-10Vdc
10mA (1K ohms min) +/- 0.1% fs |
|
General: |
|
Displays: |
Upper, 4
digits, high brightness green LED 10.4mm (0.4") high. |
|
Lower, 4
digits, high brightness orange LED 9mm (0.35") high. |
|
Digital
range 199 to 9999 |
|
Hi-res
mode 199 to 999.9 |
|
LED
output indicators flashing
SP1 square, green; SP2/SP3 round, red. |
|
Keypad: |
3
elastomeric buttons. |
|
Power
Supply: |
100-240V
AC, 50-60 Hz , (typ' 5.0 VA) |
|
Environmental: |
| Humidity: |
Max
80% |
|
Altitude: |
up to
2000M |
|
Installation: |
categories
II and III |
|
Pollution: |
Degree II |
|
Protection: |
NEMA 4X,
IP66 |
|
EMC
emission: |
EN50081-1
FCC rules 15 sub-part J class A |
|
EMC
immunity: |
EN50082-2 |
|
Ambient
temperature: |
0-50°C
(32-130°F) |
|
Moldings: |
flame
retardant polycarbonate |
|
Weight: |
180g (6.4
oz) |
|
Dimensions: |
|
Front
fascia: |
51.0 x
51.0mm (2.0" x 2.0") (includes gasket) |
|
Sleeve
length: |
106.7mm
(4.2") (with gasket fitted) |
|
Instrument
body: |
44.8 x
44.8mm (1.76" x 1.76") |
|
Overall
length: |
116.2mm
(4.57") |
|
Cutout: |
1/16 DIN - 45mm x 45mm (1.77" x
1.77") - Punches |
|
| |
Input Ranges: |
| |
|
TC |
Range |
|
Type |
°C |
°F |
|
B |
0 to 1800 °C |
32 to 3272 °F |
|
E |
0 to 600 °C |
32 to 1112 °F |
|
J |
0 to 800 °C |
32 to 1472 °F |
|
K |
-50 to 1200 °C |
-58 to 2192 °F |
|
L |
0 to 800 °C |
32 to 1472 °F |
|
N |
-50 to 1200 °C |
-58 to 2192 °F |
|
R |
0 to 1600 °C |
32 to 2912 °F |
|
S |
0 to 1600 °C |
32 to 2912 °F |
|
T |
-200 to 250 °C |
-273 to 482 °F |
|
|
Sensor |
Range |
|
Type |
°C |
°F |
|
Pt RTD 100 |
-200 to 400 °C |
-273 to 752 °F |
|
|
|
|
|
Linear Inputs |
0 - 20 mV/mA |
4 - 20 mV/mA |
|
Lin 1 |
0 - 100 |
|
|
Lin 2 |
|
0 - 100 |
|
Lin 3 |
0 - 1000 |
|
|
Lin 4 |
|
0 - 1000 |
|
Lin 5 |
0 - 2000 |
|
Note1: Use Level 3 Span and Zero
for Linear Data In Engineering Units
Note2: Use 1 ohm external shunt for mA inputs
|
|
 |
Typical Pricing:
9500 with
SSD/Relay/Relay Output
9500 w/SSD Relay/Relay + comms
9500 w/4-20mA/SSD/ Relay output
9500 w/4-20mA/SSD/ Relay output +
comms
|
237.00
292.00
289.00
344.00 |
|