Transmitters |
Transmitters are used
to send signals from one source to another. Transmitters are available in
both analog form (one analog signal in to another analog signal out) and digital
(analog signal in to digital signal out). In addition some transmitters
provide rescaling and transmission to multiple sources.
The following are
some examples of transmitters offered by Advanced Industrial Systems, Inc.
|
 |
TC Transmitter - SG 3011
|
Thermocouple Type
|
Temperature Range
°C
|
|
Type J
|
-40° ~ +760°
|
|
Type K
|
0° ~ +1000°
|
|
Type T
|
-100° ~ +400°
|
|
Type E
|
0° ~ +1000°
|
|
Type R
|
+500° ~ +1750°
|
|
Type S
|
+500° ~ +1750°
|
|
Type B
|
+500° ~ +1800°
|
|
Type N
|
-100° ~ +1300°
|
|
Type C
|
0° ~ +2000°
|
|
Type L
|
-200° ~ +800°
|
|
Type M
|
-200° ~ +100°
|
|
Type L2 (DIN 43710)
|
-200° ~ +900°
|
- Voltage Output: 0
-10V
Drive : 10mA max.
- Current Output: 0
-20mA
- Output impedance: <50Ω
- CJC offset adjustable
- OPEN Thermocouple detection
- -3dB Band Width: 5.24Hz
- Isolation (three way): 3000 Vdc
- Overload protection: 240 Vrms
- Accuracy: ±0.2% of full range
- Stability (temperature drift):
±2°
- Supply Voltage: 10~30 Vdc
- Power Consumption: 1.44W
|
|
 |
RTD
Transmitter - SG-3013
- Input Type:
Pt, Ni
- RTD Type and
Temperature Ranges:
Pt100 α=0.00385
Pt100 α=0.003916
Ni 120
Pt1000 α=0.00385
|
Pt100
|
-100°
|
to
|
+100°
|
a =0.00385
|
|
Pt100
|
0°
|
to
|
+100°
|
a =0.00385
|
|
Pt100
|
0°
|
to
|
+200°
|
a =0.00385
|
|
Pt100
|
0°
|
to
|
+600°
|
a =0.00385
|
|
Pt100
|
-100°
|
to
|
+100°
|
a =0.003916
|
|
Pt100
|
0°
|
to
|
+100°
|
a =0.003916
|
|
Pt100
|
0°
|
to
|
+200°
|
a =0.003916
|
|
Pt100
|
0°
|
to
|
+600°
|
a =0.003916
|
|
Ni120
|
-80°
|
to
|
+100°
|
|
|
Ni120
|
0°
|
to
|
+100°
|
|
|
Pt1000
|
-200°
|
to
|
+600°
|
a =0.00385
|
- Stability
Zero drift : ± 0.5uV/°C
Span drift: ±25uV/°C
- Noise Rejection
-3dB Bandwidth : 5.24Hz
CMR @ 50/60 Hz: 150 dB min
NMR @ 50/60 Hz: 100 dB
Isolation: 3000 V rms
- Input Connections :
2/3/4 wires
- Voltage Output :
0 - 5V,0 - 10V
Drive : 10mA max.
Output impedance : <50Ω
- Current Output (Source):
0 - 20mA
- Accuracy : ±0.2% of
full range
- Supply Voltage : 10~30Vdc ±10%
|
 |
Head Mounted
Industrial TC and RTD Transmitter
- Designed to provide a 4 - 20
mA output from a TC or RTD
- Convenient Head Mount
- Loop powered
- Linear output with Cold
Junction Compensation (TC)
|
 |
Thermistor Transmitter
- Designed for OEM instruments.
- Provides Linearization for 2252 ohm YSI B
Curve Thermistors or 2252 ohm US Sensor J curve thermistors and
probes
- 4 - 20 mA output
- Converts non-linear thermistor curve to a
linear output
|
Advanced Industrial
Systems, Inc.
Copyright 1997 - 2008 Advanced Industrial
Systems, Inc. All rights reserved.
Last modified:
Tuesday July 22, 2008.
|
|